What We Do

Passive Fire Protection & Life Safety Services

From fire door inspections to damper testing, firestopping, and compliance consulting — JGlaski Enterprises delivers the certified inspections and documentation your healthcare facility needs to stay survey-ready.

One Vendor. Every Passive Fire Protection Need.

Healthcare facilities face a complex web of NFPA standards, Joint Commission requirements, and CMS conditions of participation. JGlaski Enterprises covers the full scope of passive fire protection and life safety services — so you're not coordinating multiple vendors or chasing down documentation from different sources.

500+Healthcare Facilities Served
CDICertified Technicians
13+States Served
100%Survey-Ready Documentation

NFPA 80

Fire Doors

NFPA 80 · NFPA 101 · Joint Commission EC.02.03.05

Fire Door Inspections, Repairs & Relabeling

Annual inspection of fire door assemblies is required by NFPA 80 and enforced by Joint Commission and CMS surveyors. Our CDI-certified technicians inspect every component — frame, hardware, clearances, latching, and self-closing mechanisms — and document findings in a survey-ready report. When deficiencies are found, we repair on-site when possible to minimize open findings.

NFPA 90A · NFPA 105

Fire & Smoke Dampers

NFPA 90A · NFPA 105 · UL 555 · Joint Commission EC.02.03.05

Fire & Smoke Damper Testing and Remediation

Fire and smoke dampers are among the most commonly cited deficiencies in healthcare surveys — and among the most difficult to access and test. Our technicians are trained in damper access, testing procedures, and remediation per NFPA 90A and NFPA 105. We document every damper tested, every deficiency found, and every repair made.

NFPA 101 · IBC

Fire Barriers & Firestopping

NFPA 101 · IBC · UL Listed Assemblies

Fire Barrier Inspections & Firestop Systems

Penetrations through fire-rated walls, floors, and ceilings must be properly firestopped to maintain compartmentalization. We inspect through-penetration firestop systems, identify breaches, and install listed firestop assemblies to restore the fire rating. Work is documented with product data sheets and installation records for your compliance file.

NFPA 10 · NFPA 101

Fire Safety Equipment

NFPA 10 · NFPA 101 · ANSI Z358.1

Exit Lights, Extinguishers & Eye Wash Stations

Life safety equipment must be inspected and maintained on a regular schedule. We test and service exit signs, emergency lighting, portable fire extinguishers, and emergency eyewash and shower stations — keeping your facility compliant with NFPA 10, NFPA 101, and ANSI Z358.1 requirements.

Compliance Strategy

Consulting

NFPA 80 · NFPA 90A · NFPA 101 · Joint Commission · CMS

Fire & Life Safety Compliance Consulting

Not sure where your facility stands? We help healthcare organizations interpret NFPA standards, assess their current compliance posture, prepare for Joint Commission and CMS surveys, and build sustainable inspection programs. Whether you need a gap assessment or ongoing advisory support, we bring the technical expertise to help you stay ahead of surveyors.

Get Started

Schedule an Inspection or Request a Quote

Tell us about your facility and we'll respond within one business day. We serve healthcare facilities across the East Coast and nationally.

JGlaski Enterprises

Healthcare fire and life safety compliance specialists serving hospitals and healthcare facilities across the East Coast. We service nationally — give us a call if you don't see your state.

Contact

© 2026 JGlaski Enterprises. All rights reserved.

Healthcare Fire & Life Safety Compliance — East Coast & National